Pull-Wire Emergency Stop Switches |
LHPw-10/2-B-S
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Protection Class II. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHPEw-10/2-B-S
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Protection Class II. Contact – 2x module: 1x breaking and 1x making - without synchronization. Safety Category 4.
|
|
|
|
LHPw-10/2-B
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHPEw-10/2-B
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Contact – 2x module: 1x breaking and 1x making - without synchronization. Safety Category 4.
|
|
|
|
LHMw-10/2-B
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Grey cast-iron housing. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHMEw-10/2-B
|
Pull-wire emergency stop switch for a max. length up to: 2 x 50 m. Grey cast-iron housing. Contact – 2x module: 1x breaking and 1x making - without synchronization. Safety Category 4.
|
|
|
|
LHPEw-10/1-B-S
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Protection Class II. Contact – 1x module: 1x breaking and 1x making. Safety Category 2.
|
|
|
|
LHPEw-10/1-B
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Fibreglass housing. Contact – 1x module: 1x breaking and 1x making. Safety Category 2.
|
|
|
|
LHMEw-10/1-B
|
Pull-Wire Emergency Stop Switch for a max. length up to: 2 x 50 m. Grey cast-iron housing. Contact – 1x module: 1x breaking and 1x making. Safety Category 2.
|
|
|
|
Accessories
|
Accessories relating to pull-wire emergency stop switches of LH series form an integral part of the product itself. A wire, tension spring, guide loops and rings, brackets and clips, tension bolts etc.
|
|
|
|
SNS 22
|
Pull-Wire Emergency Stop Switch for a max. length up to 50 m. Grey cast-iron housing. Contact: 2x breaking. Safety Category 4. The switch is designed for small-size conveyors used in light industries.
|
|
|
|
VLS-1
|
Highlight-Flag used for pull-wire emergency stop switches – according to CSN EN ISO 13850. Sign: Emergency Stop - STOP.
|
|
|
|
Deflection Emergency Stop Switches |
LHPw-10/2-L50
|
Deflection Emergency Stop Switch having a sturdy design and an adjustable lever. Fibreglass housing. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHMw-10/2-L50
|
Deflection Emergency Stop Switch having a sturdy design and an adjustable lever. Grey cast-iron housing. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHPEw-10/1-L50
|
Deflection Emergency Stop Switch having a sturdy design and an adjustable lever. Fibreglass housing. Contact – 1x module: 1x breaking and 1x making. Safety Category 2.
|
|
|
|
LHMEw-10/1-L50
|
Deflection Emergency Stop Switch having a sturdy design and an adjustable lever. Grey cast-iron housing. Contact – 1x module: 1x breaking and 1x making. Safety Category 2.
|
|
|
|
|
Other deflection switches are given on the page featuring technology sensors for belt transport.
|
|
|
|
End Limit Switches |
LHPw-10/2-R-H
|
End Limit Emergency Stop Switch having a sturdy design and a fixed lever. Actuation at the angle of 25 degrees. Fibreglass housing. Contact – 2x module: 1x breaking and 1x making - with synchronization. Safety Category 4.
|
|
|
|
LHMw-10/2-R-H
|
End Limit Emergency Stop Switch having a sturdy design and a fixed lever. Actuation at the angle of 25 degrees. Grey cast-iron housing. Contact - 2x module: 1x breaking module and 1x making module - with synchronization. Safety Category 4.
|
|
|
|
LHPw-10/2-R-H-EX
|
End Limit Emergency Stop Switch having a sturdy design and a fixed lever. Actuation at the angle of 25 degrees. Fibreglass housing. Contact - 2x module: 1x breaking module and 1x making module - with synchronization. Safety Category 4.
|
|
|
|
LHPEw-10/1-R-H
|
End Limit Emergency Stop Switch having a sturdy design and a fixed lever. Actuation at the angle of 25 degrees. Fibreglass housing. Contact - 1x module: 1x breaking and 1x making - with synchronization. Safety Category 2.
|
|
|
|
LHMEw-10/1-R-H
|
End Limit Emergency Stop Switch having a sturdy design and a fixed lever. Actuation at the angle of 25 degrees. Grey cast-iron housing. Contact - 1x module: 1 x breaking and 1 x making - with synchronization. Safety Category 2.
|
|
|
|
|
Other end limit switches are given on the page featuring technology sensors used for belt transport.
|
|
|
|
Acoustic and Light Signalling |
FL-02
|
LED Beacon Lamp having a sturdy design and a steel basket. Stainless steel housing. Red colour version. Necessary accessories (such as brackets, clips and bushings used for looping and attaching the signal horn) are included.
|
|
|
|
IP65 SPMOD Beacon Lamp
|
LED Beacon Lamp made of hardened plastic. Red colour version.
|
|
/IMG SRC="../GRAPHICS/PICTURES/kontakt_up.gif">
|
|
IP65 SPMOD Signal Horn
|
Multipurpose Signal Horn made of hardened plastic. White colour version.
|
|
/IMG SRC="../GRAPHICS/PICTURES/kontakt_up.gif">
|
|